Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
CorSalud ; 12(3): 247-253, jul.-set. 2020. tab, graf
Article in Spanish | LILACS | ID: biblio-1154029

ABSTRACT

RESUMEN Introducción: Existen algunos estudios que relacionan parámetros de la onda P con diferentes tiempos de conducción auricular, pero no se han realizado teniendo en cuenta a cada derivación del electrocardiograma. Objetivo: Determinar la duración de la onda P (Pdur) en las 12 derivaciones y relacionarlas con el tiempo de conducción interauricular. Método: Estudio de corte transversal en 153 pacientes adultos con diagnóstico confirmado de taquicardia por reentrada intranodal (TRIN) o vías accesorias mediante estudio electrofisiológico invasivo. Resultados: Al comparar la Pdur entre sustratos arrítmicos por cada derivación, no existieron diferencias significativas, excepto en V6. En las derivaciones DII, DIII, aVR, aVF, V1 y de V3-V6 la Pdur se correlacionó con el tiempo de conducción interauricular en ambos sustratos arrítmicos. En el análisis multivariado, la Pdur constituyó un predictor independiente de tiempos de conducción interauricular ≥ 95 percentil, en las derivaciones de cara inferior y en V3, V5 y V6. Se observaron altos valores del área bajo la curva de la Característica Operativa del Receptor en las derivaciones DII (0,950; p<0,001), DIII (0,850; p<0,001) y V5 (0,891; p<0,001). Conclusiones: No existen diferencias por derivación en la Pdur al comparar casos con TRIN y vías accesorias, excepto en V6. La mayoría de las derivaciones se correlacionaron con el tiempo de conducción interauricular. La Pdur fue un predictor independiente de tiempos de conducción interauricular ≥ 95 percentil. La derivación DII presenta la mayor capacidad discriminativa para encontrar valores prolongados del tiempo de conducción interauricular.


ABSTRACT Introduction: Although some studies relate P wave parameters to different atrial conduction times, they do not consider each electrocardiogram lead separately. Objective: To determine the duration of P wave (Pdur) in the 12 leads of the electrocardiogram and relate it to the interatrial conduction time. Method: We conducted a cross-sectional study in 153 adult patients with confirmed diagnosis of atrioventricular nodal reentry tachycardia (AVNRT) or accessory pathways by invasive electrophysiological study. Results: When comparing the Pdur between arrhythmic substrates by each lead, no significant differences were found, except for V6. In leads II, III, aVR, aVF, V1 and V3-V6, Pdur was correlated with the interatrial conduction time in both arrhythmic substrates. In our multivariate analysis, the Pdur was an independent predictor of interatrial conduction times ≥ 95 percentile in inferior wall leads and in V3, V5 and V6. High values of the area under the receiver operating characteristic curve were observed in II (0.950; p<0.001), III (0.850; p<0.001) and V5 (0.891; p<0.001) leads. Conclusions: The Pdur showed no difference by leads when comparing cases with AVNRT and accessory pathways, except for V6. Most of the leads were correlated with the interatrial conduction time; Pdur was an independent predictor of interatrial conduction times ≥ 95 percentile. Lead II has the greatest discriminatory ability to find prolonged values of interatrial conduction time.


Subject(s)
Tachycardia , Electrophysiologic Techniques, Cardiac , Electrocardiography , Accessory Atrioventricular Bundle
2.
CorSalud ; 11(2): 161-166, abr.-jun. 2019. graf
Article in Spanish | LILACS | ID: biblio-1089728

ABSTRACT

RESUMEN Se presenta el caso de una paciente de 43 años, con antecedentes de salud aparente, hasta varias semanas previas a su ingreso, cuando comenzó a presentar síncopes precedidos de palpitaciones. Se realizó estudio electrofisiológico y se demostró precocidad en la porción distal del electrodo de registro de seno coronario, que corresponde a la vena cardíaca magna (interventricular anterior) y techo (summit) del ventrículo izquierdo. A pesar del excelente registro precoz se estudiaron estructuras vecinas como el tracto de salida del ventrículo izquierdo en la cúspide coronaria izquierda, aquí el mapeo eléctrico (pace mapping) no fue concordante total. En el sitio de la precocidad obtenida dentro del sistema venoso cardíaco se realizó mapeo concordante 100%, con una precocidad del catéter de ablación de -30 milisegundos. Se decidió ablación con incrementos progresivos de temperatura y potencia con corte de impedancia (termomapping) y se logró el éxito de la ablación sin reproducibilidad de la arritmia y excelente evolución posterior.


ABSTRACT The case of a 43-year-old female patient is presented, with an apparent history of good health, up to several weeks prior to admission, when she began to present syncopes preceded by palpitations. An electrophysiological study was performed and prematurity in the distal portion of the coronary sinus recording electrode was demonstrated, which corresponds to the great cardiac vein (anterior interventricular vein) and summit of the left ventricle. Despite the excellent early registration, neighboring structures were studied, such as the left ventricular outflow tract in the left coronary cusp, here the pace mapping was not totally concordant. At the site of the precocity obtained within the cardiac venous system, a 100% concordant mapping was achieved, with an ablation catheter's precocity of -30 milliseconds. The ablation was decided with progressive increases in temperature and power with thermomapping and the success of the ablation was achieved without reproducibility of the arrhythmia and excellent subsequent evolution.


Subject(s)
Electrophysiologic Techniques, Cardiac , Tachycardia, Ventricular , Atrial Premature Complexes , Radiofrequency Ablation
3.
Rev. argent. cardiol ; 80(3): 231-235, jun. 2012. tab
Article in Spanish | LILACS | ID: lil-657564

ABSTRACT

Introducción La fisiología del polo acuático ha resultado difícil de estudiar debido a sus características en el campo de juego y la electrofisiología cardíaca de estos deportistas se conoce poco, menos aún en las mujeres. La electrocardiografía del polo acuático femenino de élite se ha estudiado escasamente. Objetivos Analizar la repolarización ventricular en mujeres practicantes de polo acuático de la Preselección Nacional de Cuba. Material y métodos Estudio transversal en una muestra conformada por dos grupos de mujeres: uno de 20 deportistas y otro de 20 personas sanas no deportistas, que se compararon respecto de parámetros electrocardiográficos de repolarización ventricular. Resultados La media de edad fue de 22,45 ± 5,30 años vs. 22,45 ± 5,30 años; p > 0,05. El peso fue mayor en las deportistas (69,63 ± 7,73 kg vs. 51,20 ± 6,63 kg; p < 0,001). La media de edad deportiva fue de 13,5 años. No existieron diferencias significativas del QTc y el JTc en la derivación DII entre ambos grupos, pero fueron mayores en las deportistas en la derivación V5 (QTc: 405 ms vs. 424 ms; p < 0,05 - JTc: 307 ms vs. 329 ms; p < 0,05). La dispersión del intervalo QT fue mayor en las deportistas que en las controles (74 ms vs. 43 ms; p < 0,001), el intervalo Tpico-Tfinal (Tpeak-Tend) alcanzó valores superiores en las deportistas en las derivaciones V1 (64 ms vs. 81 ms; p < 0,05), V3 (78 ms vs. 92 ms; p < 0,05), V4 (72 ms vs. 83 ms; p < 0,05) y V5 (63 ms vs. 80 ms; p < 0,05). Conclusiones Los intervalos QTc y JTc y la dispersión del QT fueron significativamente mayores en las deportistas. El intervalo Tpico-Tfinal fue significativamente mayor en las derivaciones V1, V3, V4 y V5 en las deportistas; la dispersión del intervalo Tpico-Tfinal fue superior en las deportistas, pero no estadísticamente significativo.


Background The physiology of water polo has been difficult to study due to the characteristics of the game in the field of play. Little is known about cardiac electrophysiology in these athletes, particularly in women. The electrocardiographic variables in elite water polo athletes have been rarely studied. Objectives To analyze ventricular repolarization in female water polo players from the National Pre-selection Team of Cuba Methods A cross-sectional study was performed in two groups of women, one with 20 athletes and another with 20 healthy nonathletes. The electrocardiographic parameters of ventricular repolarization were compared between both groups. Results Mean age was 22.45±5.30 years vs. 22.45±5.30 years; p >0.05. Weight was greater in athletes compared to nonathletes (69.63±7.73 kg vs. 51.20±6.63 kg; p <0.001). Mean duration of sporting practice was 13.5 years. There were no significant differences in QTc and JTc intervals in lead DII between both groups, yet the intervals measured in lead V5 were longer in athletes (QTc: 405 ms vs. 424 ms; p <0.05 - JTc: 307 ms vs. 329 ms; p <0.05). QT interval dispersion was greater in athletes compared to non-athletes (74 ms vs. 43 ms; p <0.001). Tpeak-Tend interval was greater in athletes in leads V1 (64 ms vs. 81 ms; p <0.05), V3 (78 ms vs. 92 ms; p< 0.05), V4 (72 ms vs. 83 ms; p <0.05) and V5 (63 ms vs. 80 ms; p <0.05). Conclusions QTc and JTc intervals and QT interval dispersion were significantly greater in water polo athletes. Tpeak-Tend interval was significantly longer in leads V1, V3, V4 and V5 in the athlete group. Finally, although this group showed greater Tpeak- Tend interval dispersion, it was not statistically significant.

SELECTION OF CITATIONS
SEARCH DETAIL